English

The Fraction of the Total Current Passing Through the Galvanometer is ............ .

Advertisements
Advertisements

Question

The fraction of the total current passing through the galvanometer is ............ .

a) `S/(S+G)`

b) `G/(S+G)`

c) `(S+G)/G`

d) `(S+G)/S`

Advertisements

Solution

a) `S/(S+G)`

shaalaa.com
  Is there an error in this question or solution?
2015-2016 (July)

APPEARS IN

Video TutorialsVIEW ALL [2]

RELATED QUESTIONS

A rectangular coil of a moving coil galvanometer contains 50 turns each having area 12 cm2 . It is suspended in radial magnetic field 0.025 Wb/m2 by a fibre of twist constant 15 x10-10 Nm/degree. Calculate the sensitivity of the moving coil galvanometer.


Show that the current flowing through a moving coil galvanometer is directly proportional to the angle of deflection of coil.


Write the underlying principle of a moving coil galvanometer.


Obtain the expression for current sensitivity of moving coil galvanometer.


Draw a labelled diagram of a moving coil galvanometer. Describe briefly its principle and working.


Explain how moving coil galvanometer is converted into a voltmeter. Derive the necessary formula.


Why is it necessary to introduce a radial magnetic field inside the coil of a galvanometer?


Can a galvanometer as such be used for measuring the current? Explain.


With the help of a neat and labelled diagram, explain the principle and working of a moving coil galvanometer ?


Why does a galvanometer when connected in series with a capacitor show a momentary deflection, when it is being charged or discharged?

How does this observation lead to modifying the Ampere's circuital law?

Hence write the generalised expression of Ampere's law.


Write current sensitivity of a galvanomete S.I. unit. 


Outline the necessary steps to convert a galvanometer of resistance RG into an ammeter of a given range ?


What are the advantages of using soft iron as a core, instead of steel, in the coils of galvanometers?


A moving coil galvanometer has a coil of resistance 59 Ω. It shows a full-scale deflection for a current of 50 mA. How will you convert it to an ammeter having a range of 0 to 3A?


State how a moving coil galvanometer can be converted into an ammeter.


Explain the significance of a radial magnetic field when a current-carrying coil is kept in it. 


A galvanometer coil has a resistance of 12 Ω and the metre shows full scale deflection for a current of 3 mA. How will you convert the metre into a voltmeter of range 0 to 18 V?


The AC voltage across a resistance can be measured using a ______.


The deflection in a moving coil galvanometer is ______.


The current sensitivity of a galvanometer is defined as ______.


A moving coil galvanometer has N number of turns in a coil of effective area A, it carries a current I. The magnetic field B is radial. The torque acting on the coil is ______.

In a moving coil galvanometer the deflection (Φ) on the scale by a pointer attached to the spring is ______.


A galvanometer having a coil resistance of 60 Ω shows full-scale deflection when a current of 1.0 amp passes through it. It can be converted into an ammeter to read currents up to 5.0 amp by:


A voltmeter of variable ranges 3 V, 15 V, 150 V is to be designed by connecting resistances R1, R2, R3 in series with a galvanometer of resistance G = 20 Ω, as shown in Fig. The galvanometer gives full pass through its coil for 1 mA current i.e. "gives full pass through it's coil for 1 mA current". Then, the resistances R1, R2 and R3 (in kilo ohms) should be, respectively:


When a galvanometer is shunted with a 4 Ω resistance, the deflection is reduced to one-fifth. If the galvanometer is further shunted with a 2 Ω wire. The further reduction (find the ratio of decrease in current to the previous current) in the deflection will be (the main current remains the same)


A galvanometer coil bas 500 turns and each tum has an average area of 3 × 10-4 m2. If a torque of 1.5 Nm is required to keep this coil parallel to a magnetic field when a current of 0.5 A is flowing through it, the strength of the field (in T) is ______.


A galvanometer having a resistance of 20 Ω and 30 Ω division on both sides has figure of merit 0.005 ampere/division. The resistance that should be connected in series such that it can be used as a voltmeter upto 15 volt, is ______.


A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per millivolt. In order that each division reads 1 volt, the resistance in ohms needed to be connected in series with the coil will be ______.


A galvanometer shows full-scale deflection for current Ig. A resistance R1 is required to convert it into a voltmeter of range (0 - V) and a resistance R2 to convert it into a voltmeter of range (0 - 2V). Find the resistance of the galvanometer.


How is current sensitivity increased?


Explain in brief the basic construction of a moving-coil table galvanometer whit a neat labelled diagram.


A voltmeter has a range of 0 - 20 V and a resistance of 500 Q. Explain how can be used to measure voltages from 0 - 200 volt?


The figure below shows a circuit containing an ammeter A, a galvanometer G and a plug key K. When the key is closed:


A sensitive electromagnetic instrument used to detect and measure small electric currents (of the order of microamperes to milliamperes) by measuring the deflection of a current-carrying coil placed in a uniform magnetic field is called a:


Voltage sensitivity of a galvanometer is defined as the:


The unit in which the current sensitivity of a galvanometer is expressed is:


The voltage sensitivity of a moving coil galvanometer, where G is the resistance of the galvanometer coil, is given by:


The unit of voltage sensitivity of a galvanometer is:


Between two galvanometers, the one with the smaller figure of merit is:


When a current-carrying coil of N turns and area A, carrying current I, is placed in a magnetic field B, the magnitude of the magnetic torque acting on it is:


The use of a radial magnetic field, in which \(\sin\theta = 1\) at all positions, produces a galvanometer scale deflection that is:


In a suspended-coil galvanometer, the phosphor-bronze strip serves to:


In the pivoted-coil (Weston) type galvanometer, the two hair springs:


The non-magnetic frame of a moving coil galvanometer is made of aluminium, and its function is to provide:


An ammeter, ideally, has:


A voltmeter is connected across a component:


A circuit consists of a 3 V source and a 3 Ω resistor. With an ideal ammeter of zero resistance inserted, the current in the circuit is: