Advertisements
Advertisements
Question
Which of the following statements is correct for diamagnetic materials?
Options
μr < 1
χ is negative and low
χ does not depend on temperature
All of the above
Advertisements
Solution
All of the above.
APPEARS IN
RELATED QUESTIONS
Which of the following substances is ductile?
The susceptibility of magnesium at 200 K is 1.8 x 10-5. At what temperature will the susceptibility decrease by 6 x 10-6?
Show diagrammatically the behaviour of magnetic field lines in the presence of (i) paramagnetic and (ii) diamagnetic substances. How does one explain this distinguishing feature?
Distinguish between diamagnetic and paramagnetic substances.
A meter gauge train is heading north with speed 54 km/hr in earth's magnetic field 3 x 10-4T. The e.m.f. induced across the axle joining the wheels is ..........
(a) 0.45 mV
(b) 4.5 mV
(c) 45 mV
(d) 450 m V
The magnetic susceptibility of annealed iron at saturation is 4224. Find the permeability of
annealed iron at saturation. (μ0 = 4Π × 10−7 SI unit)
Explain Curie’s law for a paramagnetic substance.
Which of the following substances are para-magnetic?
Bi, Al, Cu, Ca, Pb, Ni
The susceptibility of a magnetic material is − 2.6 × 10−5. Identify the type of magnetic material and state its two properties.
Draw magnetic field line when a (i) diamagnetic, (ii) paramagnetic substance is placed in an external magnetic field. Which magnetic property distinguishes this behaviour of the field line due to the substances?
Identify the following magnetic materials :
Choose the correct option:
A magnetising field of 360 Am−1 produces a magnetic flux density (B) = 0.6T in a ferromagnetic material. What is its permeability in Tm A−1?
What happens to a ferromagnetic material when its temperature increases above curie temperature?
A rod of magnetic material of cross-section 0.25 cm2 is placed in a magnetizing field of intensity 4000 A/m-1. The magnetic flux passing through the rod is 25 × 10-6 Wb. Find out
(a) relative permeability
(b) magnetic susceptibility and
(c) magnetisation of the rod.
Two identical bar magnets each of magnetic moment M, separated by some distance are kept perpendicular to each other. The magnetic induction at a point at the same distance d from the centre of magnets, is (µ0 = permeability of free space)
All atoms of a magnetic substance have a resultant magnetic moment even in absence of external magnetic field. The substance is ______.
If a magnetic field is applied to a liquid in one arm of a narrow U-tube, the liquid level in that arm is lowered. The liquid in U-tube arm is ______.
There are three needles 'N1', 'N2' and 'N3' made of a ferromagnetic, a paramagnetic and a diamagnetic substance respectively. When a magnet is brought close to them, then it will ____________.
The magnetic property of magnetic substance is associated with ____________.
The product of magnetic susceptibility (`chi`) and absolute temperature (T) is constant for a ____________.
A small quantity of paramagnetic liquid is taken in a watch - glass and kept on two dissimilar magnetic poles. The liquid ____________.
Why does a paramagnetic sample display greater magnetisation (for the same magnetising field) when cooled?
If a toroid uses bismuth for its core, will the field in the core be (slightly) greater or (slightly) less than when the core is empty?
A certain region of space is to be shielded from magnetic fields. Suggest a method.
The coercivity of a small magnet where the ferromagnet gets demagnetized is 3 × 103 Am–1. The current required to be passed in a solenoid of length 10 cm and number of turns 100, so that the magnet gets demagnetized when inside the solenoid, is ______.
Assertion: A paramagnetic sample display greater magnetisation (for the same magnetic field) when cooled.
Reason: The magnetisation does not depend on temperature.
The magnetic susceptibility for diamagnetic materials is ______.
When a ferromagnetic material is created above its curie temperature
Most of the substance show which of the magnetic property:-
If a charged particle at rest experience no electromagnetic force
The universal property of all substances is ______.
According to the Atomic theory, on heating a magnet, the thermal energy of the elementary magnet ______
A paramagnetic sample shows a net magnetisation of 8 Am–1 when placed in an external magnetic field of 0.6 T at a temperature of 4 K. When the same sample is placed in an external magnetic field of 0.2 T at a temperature of 16 K, the magnetisation will be ______.
A long solenoid has 1000 turns per metre and carries a current of 1 A. It has a soft iron core of µr = 1000. The core is heated beyond the Curie temperature, Tc.
- The H field in the solenoid is (nearly) unchanged but the B field decreases drastically.
- The H and B fields in the solenoid are nearly unchanged.
- The magnetisation in the core reverses direction.
- The magnetisation in the core diminishes by a factor of about 108.
Essential difference between electrostatic shielding by a conducting shell and magnetostatic shielding is due to ______.
- electrostatic field lines can end on charges and conductors have free charges.
- lines of B can also end but conductors cannot end them.
- lines of B cannot end on any material and perfect shielding is not possible.
- shells of high permeability materials can be used to divert lines of B from the interior region.
From molecular view point, discuss the temperature dependence of susceptibility for diamagnetism, paramagnetism and ferromagnetism.
A uniform magnetic field gets modified as shown in figure when two specimens A and B are placed in it.
![]() |
![]() |
| (a) | (b) |
- Identify the specimen A and B.
- How is the magnetic susceptibility of specimen A different from that of specimen B?
Magnetic susceptibility for a paramagnetic and diamagnetic materials is respectively ______.
An ammeter of resistance R gives a full-scale deflection when a current of 2 A passes through it. If it is measured with a maximum current of 10 A, the required shunt is ______.
- Assertion (A): Diamagnetic substances exhibit magnetism.
- Reason (R): Diamagnetic materials do not have a permanent magnetic dipole moment.
Which of the following has a permeability less than that of free space?
What is magnetic hysterisis?
Explain the origin of paramagnetism on the basis of atomic structure.
Magnetic susceptibility of a diamagnetic substance ______.


