हिंदी

A Galvanometer Has a Resistance of 16ω. It Shows Full Scale Deflection, When a Current of 20 Ma is Passed Through It. the Only Shunt Resistance Available is 0.06 Which is Not Ap - Physics

Advertisements
Advertisements

प्रश्न

A galvanometer has a resistance of 16Ω. It shows full scale deflection, when a current of 20 mA is passed through it. The only shunt resistance available is 0.06  which is not appropriate to convert a galvanometer into an ammeter. How much resistance should be connected in series with the coil of galvanometer, so that the range of ammeter is 8 A?

योग
Advertisements

उत्तर

Let ‘X’ be the resistance connected in series with galvanometer.
Since S is not sufficient for I = 10 A
G = 16 Ω,

`"I"_"g"/"I" = "S"/(("G + X") + "S")`

∴ (G + X) + S = `"I"/"I"_"g""S"`

∴ `(16 + "X" + 0.06) = 8/(2 xx 10^-2) xx 0.06`

∴ (16 + X + 0.06) = 24

∴ X = 24 - 16.06

∴ X = 7.94

shaalaa.com
  क्या इस प्रश्न या उत्तर में कोई त्रुटि है?
2012-2013 (October)

APPEARS IN

वीडियो ट्यूटोरियलVIEW ALL [2]

संबंधित प्रश्न

The combined resistance of a galvanometer of resistance 500Ω and its shunt is 21Ω. Calculate the value of shunt.


A rectangular coil of a moving coil galvanometer contains 50 turns each having area 12 cm2 . It is suspended in radial magnetic field 0.025 Wb/m2 by a fibre of twist constant 15 x10-10 Nm/degree. Calculate the sensitivity of the moving coil galvanometer.


Show that the current flowing through a moving coil galvanometer is directly proportional to the angle of deflection of coil.


A galvanometer of resistance G is converted into a voltmeter to measure upto V volts by connecting a resistance R1 in series with the coil. If a resistance R2 is connected in series with it, then it can measures upto V/2 volts. Find the resistance, in terms of R1 and R2, required to be connected to convert it into a voltmeter that can read upto 2 V. Also find the resistance G of the galvanometer in terms of R1 and R2


  1. A circular coil of 30 turns and radius 8.0 cm carrying a current of 6.0 A is suspended vertically in a uniform horizontal magnetic field of magnitude 1.0 T. The field lines make an angle of 60° with the normal of the coil. Calculate the magnitude of the counter torque that must be applied to prevent the coil from turning.
  2. Would your answer change, if the circular coil in (a) were replaced by a planar coil of some irregular shape that encloses the same area? (All other particulars are also unaltered.)

Explain how moving coil galvanometer is converted into a voltmeter. Derive the necessary formula.


Can a galvanometer as such be used for measuring the current? Explain.


With the help of a neat and labelled diagram, explain the principle and working of a moving coil galvanometer ?


Define current sensitivity of a galvanometer.


Why does a galvanometer when connected in series with a capacitor show a momentary deflection, when it is being charged or discharged?

How does this observation lead to modifying the Ampere's circuital law?

Hence write the generalised expression of Ampere's law.


Define the current sensitivity of a galvanometer ?


Figure shows two circuits each having a galvanometer and a battery of 3V.

When the galvanometers in each arrangement do not show any deflection, obtain the ratio R1/R2.


Draw a labelled diagram of a moving coil galvanometer and explain its working. What is the function of radial magnetic field inside the coil?


State the principle of the working of a moving coil galvanometer, giving its labeled diagram ?


What are the advantages of using soft iron as a core, instead of steel, in the coils of galvanometers?


A coil of radius 10 cm and resistance 40 Ω has 1000 turns. It is placed with its plane vertical and its axis parallel to the magnetic meridian. The coil is connected to a galvanometer and is rotated about the vertical diameter through an angle of 180°. Find the charge which flows through the galvanometer if the horizontal component of the earth's magnetic field is BH = 3.0 × 10−5 T.


Why are the pole pieces of a horseshoe magnet in a moving coil galvanometer made cylinder in shape? 


A moving coil galvanometer has a coil of resistance 59 Ω. It shows a full-scale deflection for a current of 50 mA. How will you convert it to an ammeter having a range of 0 to 3A?


State how a moving coil galvanometer can be converted into an ammeter.


Define the term ‘current sensitivity’ of a moving coil galvanometer.


A galvanometer coil has a resistance of 12 Ω and the metre shows full scale deflection for a current of 3 mA. How will you convert the metre into a voltmeter of range 0 to 18 V?


A galvanometer coil has a resistance of 15 Ω and the metre shows full scale deflection for a current of 4 mA. How will you convert the metre into an ammeter of range 0 to 6 A?


The deflection in a moving coil galvanometer is ______.


An electric charge in uniform motion produces ______.

To make the field radial in a moving coil galvanometer ______.

In a moving coil galvanometer, the deflection of the coil θ is related to the elecrical current i by the relation ______.

The conversion of a moving coil galvanometer into a voltmeter is done by ______.


The coil of a moving coil galvanometer is wound over a metal frame in order to ______.


The current sensitivity of a galvanometer increase by 20%. If its resistance also increases by 25%, the voltage sensitivity will ______.


A galvanometer of resistance 100 Ω gives a full-scale deflection for a current of 10−5 A. To convert it into an ammeter capable of measuring up to 1 A we should connect a resistance of ______.


A galvanometer having a coil resistance of 60 Ω shows full-scale deflection when a current of 1.0 amp passes through it. It can be converted into an ammeter to read currents up to 5.0 amp by:


The coil of galvanometer consists of 100 turns and effective area of 1 square cm. The restoring couple is 10-8 N-m/rad. The magnetic field between the pole pieces is 5T. The current sensitivity of this galvanometer will be ______.


A multirange current meter can be constructed by using a galvanometer circuit as shown in figure. We want a current meter that can measure 10 mA, 100 mA and 1A using a galvanometer of resistance 10 Ω and that prduces maximum deflection for current of 1mA. Find S1, S2 and S3 that have to be used


A voltmeter of variable ranges 3 V, 15 V, 150 V is to be designed by connecting resistances R1, R2, R3 in series with a galvanometer of resistance G = 20 Ω, as shown in Fig. The galvanometer gives full pass through its coil for 1 mA current i.e. "gives full pass through it's coil for 1 mA current". Then, the resistances R1, R2 and R3 (in kilo ohms) should be, respectively:


A galvanometer coil bas 500 turns and each tum has an average area of 3 × 10-4 m2. If a torque of 1.5 Nm is required to keep this coil parallel to a magnetic field when a current of 0.5 A is flowing through it, the strength of the field (in T) is ______.


A galvanometer having a resistance of 20 Ω and 30 Ω division on both sides has figure of merit 0.005 ampere/division. The resistance that should be connected in series such that it can be used as a voltmeter upto 15 volt, is ______.


A galvanometer shows full-scale deflection for current Ig. A resistance R1 is required to convert it into a voltmeter of range (0 - V) and a resistance R2 to convert it into a voltmeter of range (0 - 2V). Find the resistance of the galvanometer.


How is current sensitivity increased?


Explain in brief the basic construction of a moving-coil table galvanometer whit a neat labelled diagram.


A resistance of 3Ω is connected in parallel to a galvanometer of resistance 297Ω. Find the fraction of current passing through the galvanometer.


A moving coil galvanometer of resistance 55 Ω produces a full scale deflection for a current of 250 mA. How will you convert it into an ammeter with a range of 0 - 3A?


Assertion: When an electric current is passed through a moving coil galvanometer, its coil gets deflected.

Reason: A circular coil produces a uniform magnetic field around itself when an electric current is passed through it.


A galvanometer of resistance 100 Ω gives a full-scale deflection for a potential difference of 200 mV.

  1. What must be the resistance connected to convert the galvanometer into an ammeter of the range 0-200 mA?
  2. Determine resistance of the ammeter.

Share
Notifications

Englishहिंदीमराठी


      Forgot password?
Use app×