हिंदी

A Circular Coil of 250 Turns and Diameter 18 Cm Carries a Current Of 12a. What is the Magnitude of Magnetic Moment Associated With the Coil?

Advertisements
Advertisements

प्रश्न

A circular coil of 250 turns and diameter 18 cm carries a current of 12A. What is the magnitude of magnetic moment associated with the coil?

Advertisements

उत्तर

M = N I A where A =π r2 

∴ M = NI π r2
∴ M = 250 x 12 x 3.14 x 81 x10-4
∴ M = 76.30 A-m2

shaalaa.com
  क्या इस प्रश्न या उत्तर में कोई त्रुटि है?
2012-2013 (March)

APPEARS IN

वीडियो ट्यूटोरियलVIEW ALL [2]

संबंधित प्रश्न

The combined resistance of a galvanometer of resistance 500Ω and its shunt is 21Ω. Calculate the value of shunt.


A rectangular coil of a moving coil galvanometer contains 50 turns each having area 12 cm2 . It is suspended in radial magnetic field 0.025 Wb/m2 by a fibre of twist constant 15 x10-10 Nm/degree. Calculate the sensitivity of the moving coil galvanometer.


Show that the current flowing through a moving coil galvanometer is directly proportional to the angle of deflection of coil.


 

Why does a galvanometer show a momentary deflection at the time of charging or discharging a capacitor? Write the necessary expression to explain this observation.


An ideal voltmeter has _______.

(A) low resistance

(b) high resistance

(C) infinite resistance

(D) zero resistance


A galvanometer of resistance G is converted into a voltmeter to measure upto V volts by connecting a resistance R1 in series with the coil. If a resistance R2 is connected in series with it, then it can measures upto V/2 volts. Find the resistance, in terms of R1 and R2, required to be connected to convert it into a voltmeter that can read upto 2 V. Also find the resistance G of the galvanometer in terms of R1 and R2


Draw a labelled diagram of a moving coil galvanometer. Describe briefly its principle and working.


  1. A circular coil of 30 turns and radius 8.0 cm carrying a current of 6.0 A is suspended vertically in a uniform horizontal magnetic field of magnitude 1.0 T. The field lines make an angle of 60° with the normal of the coil. Calculate the magnitude of the counter torque that must be applied to prevent the coil from turning.
  2. Would your answer change, if the circular coil in (a) were replaced by a planar coil of some irregular shape that encloses the same area? (All other particulars are also unaltered.)

Why is it necessary to introduce a radial magnetic field inside the coil of a galvanometer?


Can a galvanometer as such be used for measuring the current? Explain.


How will you convert a moving coil galvanometer into a voltmeter?


With the help of a neat and labelled diagram, explain the principle and working of a moving coil galvanometer ?


Define current sensitivity of a galvanometer.


Define the current sensitivity of a galvanometer ?


Figure shows two circuits each having a galvanometer and a battery of 3V.

When the galvanometers in each arrangement do not show any deflection, obtain the ratio R1/R2.


State the principle of the working of a moving coil galvanometer, giving its labeled diagram ?


Outline the necessary steps to convert a galvanometer of resistance RG into an ammeter of a given range ?


State the underlying principle of working of a moving coil galvanometer. Write two reasons why a galvanometer can not be used as such to measure current in a given circuit. Name any two factors on which the current sensitivity of a galvanometer depends.


A coil of radius 10 cm and resistance 40 Ω has 1000 turns. It is placed with its plane vertical and its axis parallel to the magnetic meridian. The coil is connected to a galvanometer and is rotated about the vertical diameter through an angle of 180°. Find the charge which flows through the galvanometer if the horizontal component of the earth's magnetic field is BH = 3.0 × 10−5 T.


Why are the pole pieces of a horseshoe magnet in a moving coil galvanometer made cylinder in shape? 


A galvanometer coil has a resistance of 12 Ω and the metre shows full scale deflection for a current of 3 mA. How will you convert the metre into a voltmeter of range 0 to 18 V?


A galvanometer coil has a resistance of 15 Ω and the metre shows full scale deflection for a current of 4 mA. How will you convert the metre into an ammeter of range 0 to 6 A?


The deflection in a moving coil galvanometer is ______.


A moving coil galvanometer has N number of turns in a coil of effective area A, it carries a current I. The magnetic field B is radial. The torque acting on the coil is ______.

To make the field radial in a moving coil galvanometer ______.

In a moving coil galvanometer, the deflection of the coil θ is related to the elecrical current i by the relation ______.

The conversion of a moving coil galvanometer into a voltmeter is done by ______.


The current sensitivity of a galvanometer increase by 20%. If its resistance also increases by 25%, the voltage sensitivity will ______.


A galvanometer of resistance 100 Ω gives a full-scale deflection for a current of 10−5 A. To convert it into an ammeter capable of measuring up to 1 A we should connect a resistance of ______.


A galvanometer having a coil resistance of 60 Ω shows full-scale deflection when a current of 1.0 amp passes through it. It can be converted into an ammeter to read currents up to 5.0 amp by:


In an ammeter 0.5% of main current passes through galvanometer; If resistance of galvanometer is G, the resistance of ammeter will be.


The coil of galvanometer consists of 100 turns and effective area of 1 square cm. The restoring couple is 10-8 N-m/rad. The magnetic field between the pole pieces is 5T. The current sensitivity of this galvanometer will be ______.


A multirange voltmeter can be constructed by using a galvanometer circuit as shown in figure. We want to construct a voltmeter that can measure 2V, 20V and 200V using a galvanometer of resistance 10Ω and that produces maximum deflection for current of 1 mA. Find R1, R2 and R3 that have to be used.


A multirange current meter can be constructed by using a galvanometer circuit as shown in figure. We want a current meter that can measure 10 mA, 100 mA and 1A using a galvanometer of resistance 10 Ω and that prduces maximum deflection for current of 1mA. Find S1, S2 and S3 that have to be used


A voltmeter of variable ranges 3 V, 15 V, 150 V is to be designed by connecting resistances R1, R2, R3 in series with a galvanometer of resistance G = 20 Ω, as shown in Fig. The galvanometer gives full pass through its coil for 1 mA current i.e. "gives full pass through it's coil for 1 mA current". Then, the resistances R1, R2 and R3 (in kilo ohms) should be, respectively:


When a galvanometer is shunted with a 4 Ω resistance, the deflection is reduced to one-fifth. If the galvanometer is further shunted with a 2 Ω wire. The further reduction (find the ratio of decrease in current to the previous current) in the deflection will be (the main current remains the same)


A galvanometer shows full-scale deflection for current Ig. A resistance R1 is required to convert it into a voltmeter of range (0 - V) and a resistance R2 to convert it into a voltmeter of range (0 - 2V). Find the resistance of the galvanometer.


How is current sensitivity increased?


Explain in brief the basic construction of a moving-coil table galvanometer whit a neat labelled diagram.


Assertion: When an electric current is passed through a moving coil galvanometer, its coil gets deflected.

Reason: A circular coil produces a uniform magnetic field around itself when an electric current is passed through it.


The figure below shows a circuit containing an ammeter A, a galvanometer G and a plug key K. When the key is closed:


A galvanometer of resistance 100 Ω gives a full-scale deflection for a potential difference of 200 mV.

  1. What must be the resistance connected to convert the galvanometer into an ammeter of the range 0-200 mA?
  2. Determine resistance of the ammeter.

Share
Notifications

Englishहिंदीमराठी


      Forgot password?
Use app×