The vernier scale of a travelling microscope has 50 divisions which coincide with 49 main scale divisions. If each main scale division is 0.5 mm, calculate the minimum inaccuracy in the measurement of distance.

Short/Brief Note
Advertisements

Solution

A Diagram of the vernier calliper is shown below.


According to the problem, 50 divisions of the Vernier scale coincide with 49 main scale divisions.

50 VSD = 49 MSD

⇒ 1 MSD = `50/49` VSD or 1 VSD = `49/50` MSD

Where MSD = Main scale division and VSD = Vernier scale division.

We know that

Minimum inaccuracy = Vernier constant

= 1 MSD – 1 VSD

= 1 MSD – `49/50` MSD = `1/50` MSD

It is given in the problem that 1 MSD = 0.5 mm

Hence, minimum inaccuracy = `1/50 xx 0.5` mm = `1/100` = 0.01 mm

shaalaa.com
  Is there an error in this question or solution?
Chapter 2: Units and Measurements - Exercises [Page 9]

APPEARS IN

NCERT Exemplar Physics [English] Class 11
Chapter 2 Units and Measurements
Exercises | Q 2.28 | Page 9

RELATED QUESTIONS

The error in the measurement of the sides of a rectangle is 1%. The error in the measurement of its area is ______.


Define relative error.


The masses of two bodies are measured to be 15.7 ± 0.2 kg and 27.3 ± 0.3 kg. What is the total mass of the two and the error in it?


In Ohm’s experiments, the values of the unknown resistances were found to be 6.12 Ω, 6.09 Ω, 6.22 Ω, 6.15 Ω. Calculate the (mean) absolute error, relative error, and percentage error in these measurements.


Solve the numerical example.

If the formula for a physical quantity is X = `("a"^4"b"^3)/("c"^(1//3)"d"^(1//2))` and if the percentage error in the measurements of a, b, c and d are 2%, 3%, 3% and 4% respectively. Calculate percentage error in X.


In an experiment, the percentage of error occurred in the measurement of physical quantities A, B, C and D are 1%, 2%, 3% and 4% respectively. Then the maximum percentage of error in the measurement X, where X = `(A^2B^(1/2))/(C^(1/3)D^3)`, will be:


Measure of two quantities along with the precision of respective measuring instrument is A = 2.5 ms–1 ± 0.5 ms–1 B = 0.10 s ± 0.01 s. The value of A B will be ______.


You measure two quantities as A = 1.0 m ± 0.2 m, B = 2.0 m ± 0.2 m. We should report correct value for `sqrt(AB)` as ______.


The mean length of an object is 5 cm. Which of the following measurements is most accurate?


A physical quantity X is related to four measurable quantities a, b, c and d as follows: X = a2 b3 c5/2d–2. The percentage error in the measurement of a, b, c and d are 1%, 2%, 3% and 4%, respectively. What is the percentage error in quantity X? If the value of X calculated on the basis of the above relation is 2.763, to what value should you round off the result.


In a Screw Gauge, the fifth division of the circular scale coincides with the reference line when the ratchet is closed. There are 50 divisions on the circular scale, and the main scale moves by 0.5 mm on a complete rotation. For a particular observation, the reading on the main scale is 5 mm and the 20th division of the circular scale coincides with the reference line. Calculate the true reading.


A travelling microscope has 20 divisions per cm on the main scale while its Vernier scale has total 50 divisions and 25 Vernier scale divisions are equal to 24 main scale divisions, what is the least count of the travelling microscope?


A travelling microscope is used to determine the refractive index of a glass slab. If 40 divisions are there in 1 cm on main scale and 50 Vernier scale divisions are equal to 49 main scale divisions, then least count of the travelling microscope is ______ × 10-6 m. 


What is an error in measurement?


What are random errors?


Which strategy would best reduce an instrumental error caused by a faulty weighing scale?


If the pointer of the voltmeter is not exactly at the zero of the scale, then the error is called ______.


Instrumental error can be minimised by ______.


Error due to non-removal of parallax between pointer and its image in case of magnetic compass needle causes ______.


Share
Notifications

Englishहिंदीमराठी


      Forgot password?
Use app×