English

How is current sensitivity increased? - Physics

Advertisements
Advertisements

Questions

How is current sensitivity increased?

Briefly describe how the current sensitivity of a moving coil galvanometer can be increased.

Short/Brief Note
Advertisements

Solution

A moving coil galvanometer's sensitivity can be enhanced by increasing the number of turns in the coil, the area of the coil, and the magnetic field, while decreasing the couple per unit twist of the suspension.

shaalaa.com
  Is there an error in this question or solution?
2015-2016 (March) Foreign Set 2

Video TutorialsVIEW ALL [2]

RELATED QUESTIONS

A rectangular coil of a moving coil galvanometer contains 50 turns each having area 12 cm2 . It is suspended in radial magnetic field 0.025 Wb/m2 by a fibre of twist constant 15 x10-10 Nm/degree. Calculate the sensitivity of the moving coil galvanometer.


An ideal voltmeter has _______.

(A) low resistance

(b) high resistance

(C) infinite resistance

(D) zero resistance


Draw a labelled diagram of a moving coil galvanometer. Describe briefly its principle and working.


  1. A circular coil of 30 turns and radius 8.0 cm carrying a current of 6.0 A is suspended vertically in a uniform horizontal magnetic field of magnitude 1.0 T. The field lines make an angle of 60° with the normal of the coil. Calculate the magnitude of the counter torque that must be applied to prevent the coil from turning.
  2. Would your answer change, if the circular coil in (a) were replaced by a planar coil of some irregular shape that encloses the same area? (All other particulars are also unaltered.)

A rectangular coil of a moving coil galvanometer contains 100 turns, each having area
15 cm2. It is suspended in the radial magnetic field 0.03 T. The twist constant of suspension
fibre is 15 x 10-10 N-m/degree. Calculate the sensitivity of the moving coil galvanometer.


In the meter bridge experiment, balance point was observed at J with AJ = l.

(i) The values of R and X were doubled and then interchanged. What would be the new position of balance point?

(ii) If the galvanometer and battery are interchanged at the balance position, how will the alance point get affected?


State the principle of the working of a moving coil galvanometer, giving its labeled diagram ?


A moving coil galvanometer has a coil of resistance 59 Ω. It shows a full-scale deflection for a current of 50 mA. How will you convert it to an ammeter having a range of 0 to 3A?


The AC voltage across a resistance can be measured using a ______.


The current sensitivity of a galvanometer is defined as ______.


Share