Question
Define Mean absolute error.
Advertisements
Solution
For a given set of measurements of the same quantity, the arithmetic mean of all the absolute errors is called mean absolute error in the measurement of that physical quantity.
`triangle "a"_"mean" = (triangle"a"_1 + triangle"a"_2 + ......+ triangle"a"_"n")/"n" = 1/"n"` \[\sum_{i=1}^n\triangle a_i\]
APPEARS IN
RELATED QUESTIONS
The error in the measurement of the sides of a rectangle is 1%. The error in the measurement of its area is ______.
Define percentage error.
If the measured values of the two quantities are A ± ΔA and B ± ΔB, ΔA and ΔB being the mean absolute errors. What is the maximum possible error in A ± B? Show that if Z = `"A"/"B"`
`(Delta "Z")/"Z" = (Delta "A")/"A" + (Delta "B")/"B"`
In a workshop, a worker measures the length of a steel plate with Vernier calipers having a least count 0.01 cm. Four such measurements of the length yielded the following values: 3.11 cm, 3.13 cm, 3.14 cm, 3.14 cm. Find the mean length, the mean absolute error, and the percentage error in the measured value of the length.
In Ohm’s experiments, the values of the unknown resistances were found to be 6.12 Ω, 6.09 Ω, 6.22 Ω, 6.15 Ω. Calculate the (mean) absolute error, relative error, and percentage error in these measurements.
In an experiment, the percentage of error occurred in the measurement of physical quantities A, B, C and D are 1%, 2%, 3% and 4% respectively. Then the maximum percentage of error in the measurement X, where X = `(A^2B^(1/2))/(C^(1/3)D^3)`, will be:
If Q = `"X"^"n"/"Y"^"m"` and Δx is absolute error in the measurement of X, Δy is absolute error in the measurement of Y, then absolute error ΔQ in Q is ______.
Measure of two quantities along with the precision of respective measuring instrument is A = 2.5 ms–1 ± 0.5 ms–1 B = 0.10 s ± 0.01 s. The value of A B will be ______.
You measure two quantities as A = 1.0 m ± 0.2 m, B = 2.0 m ± 0.2 m. We should report correct value for `sqrt(AB)` as ______.
The mean length of an object is 5 cm. Which of the following measurements is most accurate?
The vernier scale of a travelling microscope has 50 divisions which coincide with 49 main scale divisions. If each main scale division is 0.5 mm, calculate the minimum inaccuracy in the measurement of distance.
A physical quantity X is related to four measurable quantities a, b, c and d as follows: X = a2 b3 c5/2d–2. The percentage error in the measurement of a, b, c and d are 1%, 2%, 3% and 4%, respectively. What is the percentage error in quantity X? If the value of X calculated on the basis of the above relation is 2.763, to what value should you round off the result.
The resistance R = `"V"/"I"`, where V = (50 ± 2) V and I = (20 ± 0.2)A. The percentage error in R is 'x' %.
The value of x to the nearest integer is ______.
In a Screw Gauge, the fifth division of the circular scale coincides with the reference line when the ratchet is closed. There are 50 divisions on the circular scale, and the main scale moves by 0.5 mm on a complete rotation. For a particular observation, the reading on the main scale is 5 mm and the 20th division of the circular scale coincides with the reference line. Calculate the true reading.
The dependence of g on geographical latitude at sea level is given by `g = g_0(1 + betasin^2Phi)` where Φ is the latitude angle and β is a dimensionless constant. If Δg is the error in the measurement of g then the error in measurement of latitude angle is ______.
The least count of the main scale of a screw gauge is 1 mm. The minimun number of divisions on its circular scale required to measure 5 µm diameter of a wire is ______.
If the zero of the vernier lies on the right-hand side and the fourth division coincides with the main scale division when the jaws are in contact so the correction will be ______.
A thermometer always reads 2°C higher than the actual temperature because its zero mark is incorrect. What type of error is this?
Which statement best describes the effect of systematic errors on measurements?
Which one of the following is an effective way to reduce systematic errors in an experiment?
If the pointer of the voltmeter is not exactly at the zero of the scale, then the error is called ______.
Instrumental error can be minimised by ______.
Error due to non-removal of parallax between pointer and its image in case of magnetic compass needle causes ______.