Advertisements
Advertisements
प्रश्न
Define coefficient of mutual induction.
Advertisements
उत्तर
Coefficient of mutual induction is defined as the e.m.f induced in the secondary coil per unit rate of change of current in the primary coil (neighbouring coil).
APPEARS IN
संबंधित प्रश्न
If the radius of a sphere is doubled without changing the charge on it, then electric flux originating from the sphere is ______.
Explain the meaning of the term mutual inductance.
Draw a necessary arrangement for winding of primary and secondary coils in a step-up transformer. State its underlying principle and derive the relation between the primary and secondary voltages in terms of number of primary and secondary turns. Mention the two basic assumptions used in obtaining the above relation.
Define mutual inductance.
In an experiment, two coils c1 and c2 are placed close to each other. Find out the expression for the emf induced in the coil c1 due to a change in the current through the coil c2.
The current flowing through an inductor of self inductance L is continuously increasing. Plot a graph showing the variation of Magnetic potential energy stored versus the current.
An air-cored solenoid with length 30 cm, area of cross-section 25 cm2 and number of turns 500, carries a current of 2.5 A. The current is suddenly switched off in a brief time of 10−3 s. How much is the average back emf induced across the ends of the open switch in the circuit? Ignore the variation in magnetic field near the ends of the solenoid.
A coil of self-inductance 2.5H and resistance 20Ω is connected to a battery of emf 120V having the internal resistance of 5 n. Find:
1) The time constant of the circuit.
2) The current in the circuit in steady state
Find the mutual inductance between the straight wire and the square loop of figure.

Find the mutual inductance between the circular coil and the loop shown in figure.

The current in a long solenoid of radius R and having n turns per unit length is given by i= i0 sin ωt. A coil having N turns is wound around it near the centre. Find (a) the induced emf in the coil and (b) the mutual inductance between the solenoid ant the coil.
A solenoid of length 20 cm, area of cross-section 4.0 cm2 and having 4000 turns is placed inside another solenoid of 2000 turns having a cross-sectional area 8.0 cm2 and length 10 cm. Find the mutual inductance between the solenoids.

A pair of adjacent coils has a mutual inductance of 1.5 H. If the current in one coil changes from 0 to 10 A in 0.2 s, what is the change of flux linkage with the other coil?
An emf of 96.0 mV is induced in the windings of a coil when the current in a nearby coil is increasing at the rate of 1.20 A/s. What is the mutual inductance (M) of the two coils?
A long solenoid of length l, cross-sectional area A and having N1 turns (primary coil), has a small coil of N2 turns (secondary coil) wound about its center. Determine the Mutual inductance (M) of the two coils.
The mutual inductance of two coils is 10 mH. If the current in one of the coil changes from 5 A to 1 A in 0.2 s, calculate the emf induced in the other coil. Also calculate the induced charge flowing through the coil if its resistance is 5 Ω.
A pair of the adjacent coil has a mutual inductance of 1.5 H. If the current in one coil varies from 0 to 20 A in 0.5 s, what is the change of flux linked with the other coil.
Define mutual inductance.
The dimensions of self or mutual inductance are given as ______.
In mutual induction, the main current remains same because ____________.
In an induction coil, the coefficient of mutual inductance is 6 henry. If a current of 10 ampere in the primary coil is cut-off in `1/1500"s"`, the e.m.f. at the terminals of the secondary coil will be ____________.
An alternating current of frequency 200 rad/s and peak value 1 A is applied to the primary of a transformer. If the coefficient of mutual induction between the primary and the secondary is 1.5H, then the voltage induced in the secondary will be approximately (π = 2217)
A coil of radius 'r' is placed on another coil (whose radius is 'R' and current flowing through it is changing) so that their centres coincide. (R>>r) if both the coils are coplanar then the mutual inductance between them is proportional to ______.
Two different wire loops are concentric and lie in the same plane. The current in the outer loop (I) is clockwise and increases with time. The induced current in the inner loop.
The mutual inductance between two coplanar concentric rings A and B of radii 'R1' and 'R2' placed in air when a current 'I' flows through ring A is (R1 >> R2) (µ0 = permeability of free space) ____________.
The mutual inductance of a pair of coils is 0.75 H. If current in the primary coil changes from 0.5 A to zero in 0.01 s, find average induced e.m.f. in secondary coil ______.
Two coils are placed close to each other. The mutual inductance of the pair of coils depends upon the ______.
Two circular coils have their centres at the same point. The mutual inductance between them will be maximum when their axes ______
There are two coils A and B seperated by some distance. If a current of 2A flows through A, a magnetic flux of 10-2 Wb passes through B (no current through B). If no current passes through A and a current of 1A passes through B, what is the flux through A?
A plane loop is shaped in the form as shown in figure with radii a = 20 cm and b = 10 cm and is placed in a uniform time varying magnetic field B = B0 sin ωt, where B0 = 10 mT and ω = 100 rad/s. The amplitude of the current induced in the loop if its resistance per unit length is equal to 50 × 10-3 Ω/m. The inductance of the loop is negligible is ______ A.

A toroid is a long coil of wire wound over a circular core. The major radius and cross-sectional radius of the toroid are R and r, respectively. The coefficient of mutual induction of the toroid is ______.
(The magnetic field in it is uniform, N = number of turns, R >> r, μ0 = permeability of free space)
Write the S.I. unit of mutual inductance.
A rectangular coil of wire 50 turn each of area 6 x 10-4 m2 is freely suspended in a field of 3 x 10-2 Wb / m2. Calculate the current flowing through the coil when it deflects through 60°, when torsional constant is 3.82 x 10-6 SI unit.
The coefficient of mutual induction is 2 H and induced e.m.f. across secondary is 2 kV. Current in the primary is reduced from 6 A to 3 A. The time required for the change of current is ______.
The mutual inductance between a primary and secondary circuit is 0.4 H and the resistance in these circuits are \[20\Omega\] and \[4\Omega\] respectively. To produce a current of 0.5 A in the secondary, current in the primary must be changed at the rate of ______.
Two coils are placed close to each other. The mutual inductance of the pair of coils depends upon ______.
The value of mutual inductance of two coils is 6 mH. The current in one of the coil changes from 6 A to 1 A in 0.2 second so that e.m.f. is induced in the other coil. If the resistance of the coil is 6 Ω, the value of induced charge passing through the coil is ______.