Advertisements
Advertisements
प्रश्न
The 300 turn primary of a transformer has resistance 0.82 Ω and the resistance of its secondary of 1200 turns is 6.2 Ω. Find the voltage across the primary if the power output from the secondary at 1600V is 32 kW. Calculate the power losses in both coils when the transformer efficiency is 80%
Advertisements
उत्तर
Given data:
NP = 300, NS = 1200, VS = 1600 V, RP = 0.82Ω,
RS = 6.2Ω, PS = 32 KW
1) PS = VSIS
`"I"_"S" = "P"_"S"/"V"_"S"`
`= 32000/1600`
IS = 20 A
2) `"V"_"P"/"V"_"S" = "N"_"P"/"N"_"S"`
`"V"_"P" = 300/1200 xx 1600`
= 400 V
3) η = `"P"_"S"/("V"_"p""I"_"p")`
`= 80/100 = 32000/(400 xx "I"_"p") = 32000/320`
Ip = 100 A
4) Power loss in primary = (IP)2 × RP
= 100 × 1000 × 0.82
= 0.82 × 1000
= 8.2000 = 8.2 KW
5) Power loss in secondary = (IS)2 × RS
= 20 × 20 × 6.2
= 400 × 6.2
= 2480 W = 2.48 KW
APPEARS IN
संबंधित प्रश्न
Describe briefly and two energy losses, giving the reasons for their occurrence in actual transformers ?
Describe briefly, with the help of labelled diagram, working of a step-up transformer.
A step-up transformer converts a low voltage into high voltage. Does it not violate the principle of conservation of energy? Explain.
An ideal transformer has 100 turns in the primary and 250 turns in the secondary. The peak value of the AC is 28 V. The rms secondary voltage is nearest to ______
Distinguish between Step up and Step Down Transformer.
Devices which is used to convert high alternating current to low alternating current is ______.
A power transmission line feeds input power at 2300 V to a stepdown transformer with its primary windings having 4000 turns. What should be the number of turns in the secondary in order to get output power at 230 V?
A transformer is used ______
Magnetic flux passing through a coil is initially 4 × 10-4 Wb. It reduces to 10% of its original value in t second. If the emf induced is 0. 72 mV then t in second is ______.
An iron rod of 0.2 cm2 cross-sectional area is subjected to a magnetising field of 1200 Am-1. If the susceptibility of iron is 599, then the magnetic flux produced is ______.