Advertisements
Advertisements
प्रश्न
Figure shows a screw gauge in which circular scale has 100 divisions. Calculate the least count and the diameter of a wire.

Advertisements
उत्तर
No. of circular scale division = 100
Pitch =0.5 mm
= `(0.5 "mm")/100`
= 0.005 mm
L.C. = 0.005 mm = 0.0005 cm
Main scale reading = 4.5 mm = 0.45 cm
(C.S.D.) circular scale reading = 73 division
Observed diameter of wire = Main scale reading + L.C. × C.S.D.
= 0.45 + 0.0005 × 73
= 0.45 + 0.0365
= 0.4865 cm
APPEARS IN
संबंधित प्रश्न
Name the part of the vernier callipers which is used to measure the following
Depth of a small bottle
Explain the terms : Least count of a screw gauge.
How are they determined?
State the purpose of ratchet in a screw gauge.
A micrometre screw gauge has a negative zero error of 7 divisions. While measuring the diameter of a wire the reading on the main scale is 2 divisions and 79th circular scale division coincides with baseline.
If the number of divisions on the main scale is 10 to a centimetre and circular scale has 100 divisions, calculate
- pitch
- observed diameter
- least count
- corrected diameter.
Explain the term least count of a screw gauge. How are they determined?
What is the least count in the case of the following instrument?
Thermometer
Consider the following case where the zero of vernier scale and the zero of the main scale are clearly seen. If L.C. of the vernier calipers is 0.01 cm, write the zero error and zero correction of the following.

Consider the following case where the zero of vernier scale and the zero of the main scale are clearly seen. If L.C. of the vernier calipers is 0.01 cm, write the zero error and zero correction of the following.

In a vernier calipers, (N + 1) divisions of vernier scale coincide with N divisions of main scale. If 1 MSD represents 0.1 mm, the vernier constant (in cm) is ______.