Fig . shows the core of a transformer and i ts input and output connections

State the material used for the core and describe th e structure of the core.
(a) Use the values given in the diagram to calculate the turns ratio for the transformer and connections, labeling all parts of the diagram .
(b) If a current of 2 A is taken from th e output, calculate th e current in the input circuit (Assume the transformer to be ideal ).
Advertisements
उत्तर
(a) Soft iron is used as the material for the core of transformer.
Structure of core: The core is made by taking thin rectangular sheets or laminas of soft iron (or silicon -steel) and dipping them in an insulating paint or varnish . These insulated sheets are stacked together to form a solid looking rectangular frame. This is called the laminated core of the transformer.
(b) Given, Ep = 250 V, E. =50 V
We know that for transformer turn ratio = `"N"_"s"/"N"_"p" = "E"_"s"/"E"_"p"`
`"N"_"s"/"N"_"P" = 50/250 = 1/5`
Thus, it is a step-down transformer.

Given, Is =2A
Let Ip be the current though primary.
We know that for transformer turn ratio = `"I"_"p"/"I"_"s" = "E"_"s"/"E"_"s" = 1/5`
Ip = `1/5 xx 2 = 0.4 "A"`
APPEARS IN
संबंधित प्रश्न
1 A = _________ mA
- 102
- 103
- 10-3
- 10-6
Three 2 V cells are connected in series and used as a battery in a circuit.
How many joules of electrical energy does 1 C gain on passing through (i) one cell (ii) all three cells?
A Radio Set Draws a Current of 0.36 a for 15 Minutes. Calculate the Amount of Electric Charge that Flows Through the Circuit.
Give three reasons why different electrical appliances in a domestic circuit are connected in parallel.
If the current passing through a conductor is doubled, what will be the change in heat produced
Tick(✓) the correct choice in the following:
A three pin plug is connected to the lead for a 1 kW electric iron to be
used on a 250 V supply. Which of the following statements is not correct?
Explain, why the potential difference across the terminals of a cell is more when the cell is not in use than it is when the cell is being used.