मराठी

Draw a Labeled Diagram of a Step-down Transformer. - Physics

Advertisements
Advertisements

प्रश्न

Draw a labeled diagram of a step-down transformer.

Advertisements

उत्तर

Step-down transformer

 

shaalaa.com
  या प्रश्नात किंवा उत्तरात काही त्रुटी आहे का?
2015-2016 (March) All India Set 2 C

व्हिडिओ ट्यूटोरियलVIEW ALL [3]

संबंधित प्रश्‍न

A transformer converts 240 V AC to 60 V AC. The secondary has 75 turns. The number of turns in primary are _______.

(A) 600

(B) 500

(C) 400

(D) 300

 


The primary coil of a transformed has 800 urns and the secondary coil has 8 turns. It is connected to a 220 V a.c. supply. What will be the output voltage?


Draw a labeled diagram of a full wave rectifier circuit. State its working principle. Show the input-output waveforms ?


Distinguish between Step up and Step Down Transformer.


In a series resonant RLC circuit, the voltage across 100 Ω resistor is 40 V. The resonant frequency ω is 250 rad/s. If the value of C is 4 µF, then the voltage across L is


A transformer is essentially an a.c. device. It cannot work on d.c. It changes alternating voltages or currents. It does not affect the frequency of a.c. It is based on the phenomenon of mutual induction. A transformer essentially consists of two coils of insulated copper wire having different numbers of turns and wound on the same soft iron core.

The number of turns in the primary and secondary coils of an ideal transformer is 2000 and 50 respectively. The primary coil is connected to a main supply of 120 V and secondary coil is connected to a bulb of resistance 0.6 Ω.

Power in primary coil is ______.


The primary winding of a transformer has 100 turns and its secondary winding has 200 turns. The primary is connected to an a.c supply of 120 V and the current flowing in its is 10 A. The voltage and the current in the secondary are ______.


The line that draws power supply to your house from street has ______.

  1. zero average current.
  2. 220 V average voltage.
  3. voltage and current out of phase by 90°.
  4. voltage and current possibly differing in phase `phi` such that `|phi| < pi/2`.

1 MW power is to be delivered from a power station to a town 10 km away. One uses a pair of Cu wires of radius 0.5 cm for this purpose. Calculate the fraction of ohmic losses to power transmitted if

  1. power is transmitted at 220 V. Comment on the feasibility of doing this.
  2. a step-up transformer is used to boost the voltage to 11000 V, power transmitted, then a step-down transfomer is used to bring voltage to 220 V. (ρCu = 1.7 × 10–8 SI unit)

An ideal transformer converts 170 V a.c. to 1.70 KV a.c. to transmit a power of 3.4 KW. If primary coil has 500 turns then alternating current in secondary coil is ______.