हिंदी
कर्नाटक बोर्ड पी.यू.सी.पीयूसी विज्ञान कक्षा ११

Find the Time Required for a 50 Hz Alternating Current to Change Its Value from Zero to the Rms Value. - Physics

Advertisements
Advertisements

प्रश्न

Find the time required for a 50 Hz alternating current to change its value from zero to the rms value.

योग
Advertisements

उत्तर

Frequency of alternating current, f = 50 Hz
Alternation current ( i ) is given by,
 i = i0sinωt   ...(1)
Here, i0 = peak value of current
Root mean square value of current `(i_rms)` is given by,

`i_{rms } = i_0/ sqrt2  .......(1)`
 On substituting the value of the root mean square value of current in place of alternating current in equation (1), we get:

`i_0 / sqrt2 = i_0 sin  omega t`

⇒ `1/sqrt2 = sin omega t = sin  pi/4`

⇒ t =` pi/(4 omega) = pi/(4xx2pif)`   `(therefore (i) = 2pif)`

= `1/(8f) = 1/(8xx50) `

=`1/400 = 0.0025 s`
= 2.5 ms

shaalaa.com
  क्या इस प्रश्न या उत्तर में कोई त्रुटि है?
अध्याय 17: Alternating Current - Exercises [पृष्ठ ३३०]

APPEARS IN

एचसी वर्मा Concepts of Physics Vol. 2 [English] Class 11 and 12
अध्याय 17 Alternating Current
Exercises | Q 1 | पृष्ठ ३३०

संबंधित प्रश्न

In a series LCR circuit connected to an ac source of variable frequency and voltage ν = vm sin ωt, draw a plot showing the variation of current (I) with angular frequency (ω) for two different values of resistance R1 and R2 (R1 > R2). Write the condition under which the phenomenon of resonance occurs. For which value of the resistance out of the two curves, a sharper resonance is produced? Define Q-factor of the circuit and give its significance.


The voltage and current in a series AC circuit are given by V = V0cos ωt and i = i0 sin ωt. What is the power dissipated in the circuit?


Two alternating currents are given by `i_1 = i_0 sin wt and i_2 = i_0 sin (wt + pi/3)` Will the rms values of the currents be equal or different?


Can the peak voltage across the inductor be greater than the peak voltage of the source in an LCR circuit?


An alternating current is given by i = i1 cos ωt + i2 sin ωt. The rms current is given by


An alternating current of peak value 14 A is used to heat a metal wire. To produce the same heating effect, a constant current i can be used, where i is


An electric bulb is designed to operate at 12 volts DC. If this bulb is connected to an AC source and gives normal brightness, what would be the peak voltage of the source?


The peak power consumed by a resistive coil, when connected to an AC source, is 80 W. Find the energy consumed by the coil in 100 seconds, which is many times larger than the time period of the source.


The dielectric strength of air is 3.0 × 106 V/m. A parallel-plate air-capacitor has area 20 cm2 and plate separation 0.10 mm. Find the maximum rms voltage of an AC source that can be safely connected to this capacitor.


A coil of inductance 5.0 mH and negligible resistance is connected to the oscillator of the previous problem. Find the peak currents in the circuit for ω = 100 s−1, 500 s−1, 1000 s−1.


Answer the following question.
A small town with a demand of 1200 kW of electric power at 220 V is situated 20 km away from an electric plant generating power at 440 V. The resistance of the two wirelines carrying power is 0.5 Ω per km. The town gets the power from the line through a 4000-220 V step-down transformer at a sub-station in the town. Estimate the line power loss in the form of heat. 


The peak voltage of an ac supply is 300 V. What is the rms voltage?


A circuit containing a 80 mH inductor and a 60 µF capacitor in series is connected to a 230 V, 50 Hz supply. The resistance of the circuit is negligible.

(a) Obtain the current amplitude and rms values.

(b) Obtain the rms values of potential drops across each element.

(c) What is the average power transferred to the inductor?

(d) What is the average power transferred to the capacitor?

(e) What is the total average power absorbed by the circuit?
[‘Average’ implies ‘averaged over one cycle’.]


Do the same with the replacement of the earlier transformer by a 40,000-220 V step-down transformer (Neglect, as before, leakage losses though this may not be a good assumption any longer because of the very high voltage transmission involved). Hence, explain why high voltage transmission is preferred?


The peak value of the a.c. current flowing throw a resistor is given by ______.

When a voltage measuring device is connected to AC mains, the meter shows the steady input voltage of 220V. This means ______.


The output of a step-down transformer is measured to be 24 V when connected to a 12-watt light bulb. The value of the peak current is ______.


Share