State relative advantages and disadvantages of ring system of wiring over the tree system.
Advertisements
उत्तर
Advantages:
(i) The tree system of wiring requires the plugs and sockets of different sizes for different current capacities while they are all of the same sizes in the ring system of wiring.
(ii) The tree system of wiring has one fuse in one distribution line. If the fuse in one distribution line blows, it disconnects all the appliances in that distribution line. But in the ring system, a separate fuse is connected with each appliance. So if one fuse blows, it does not affect the other appliances.
(iii) The tree system of wiring is expensive while the ring system of wiring is cheaper.
(iv) It is expensive and inconvenient to install a new appliance in the tree system of wiring since it requires to put the new leads up to the distribution box, while it is easy to install a new appliance in the ring system since the appliance can be directly connected to ring mains in the room.
Disadvantages:
The only disadvantage of the ring system of wiring over the tree system is that while installing a new appliance, care has to be taken that the total load on the ring circuit does not exceed the main fuse rating (i.e., generally 30 amp.).
संबंधित प्रश्न
What is the meaning of the symbol kWh? Which quantity does it represent?
Calculate the cost of operating a heater of 500 W for 20 hours at the rate of Rs 3.90 per unit.
Electrical power p is given by the expression P = (Q × V) ÷ time. Express the power P in terms of current and resistance explaining the meaning of symbols used there in.
An electrical appliance having a resistance of 200Ω is operated at 200 V. Calculate the energy consumed by the appliance in 5 minutes (i) in joules (ii) in kWh.
What is the current I in the given circuit (Fig. )?

Write the SI units for:
(a) Electric current
(b) Potential difference
(c) Charge.
A coil of copper wire is connected to a galvanometer. What would happen if a bar magnet is:
(i) Pushed into the coil with its north pole entering first?
(ii) Held at rest inside the coil?
(iii) Pulled out again?
What would happen and why, to an electric bulb when it is connected across a supply of voltage (i) lower (ii) higher than its proper rating?
You are required to connect a bulb, a fan and a socket outlet to the mains in one set A and an air-conditioner and a refrigerator to the mains in other set B. Will you recommend the wire of same thickness and same insulation in both? explain your answer.
Find the cost of operating an electric toaster for two hours if it draws 8 A current on a 110 volt circuit. The cost of electrical energy is Rs. 2.50 per kWh.