Two moving coil galvanometers G1 and G2 are identical except for the following features:

Features G1 G2
Number of turns 50 60
Area of the coil 30 cm2 40 cm2
Resistance of the coil 4 Ω 6 Ω

Perform calculations to determine which galvanometer has greater current sensitivity.

संख्यात्मक
Advertisements

उत्तर

To determine which galvanometer has greater current sensitivity, we use the formula for the current sensitivity of a moving coil galvanometer:

S = `(NBA)/(kR)`

Given that the two galvanometers have the same magnetic field strength (B) and the same constant (k), we can compare their current sensitivities using the remaining parameters: the number of turns (N), the area of the coil (A), and the coil resistance (R).

The relative sensitivity for G1.

N1 = 50

A1 = 30 cm2

R1 = 4 Ω

`S_1 = (N_1 xx A_1)/(R_1)`

= `(50 xx 30)/4`

= `1500/4`

= 375

The relative sensitivity for G2.

N2 = 60

A2 = 40 cm2

R2 = 6 Ω

`S_2 = (N_2 xx A_2)/(R_2)`

= `(60 × 40)/6`

= `2400/6` 

= 400

∴ S2 > S1 

400 > 375

Because the galvanometer G2 has greater current sensitivity than the galvanometer G1.