Advertisements
Advertisements
प्रश्न
An immersion rod having resistance of 50 Ω is connected to 220V main supply. Assuming that all the energy generated goes to heat the water, calculate the time taken to heat 5 kg water from 30°C to 100°C.
Advertisements
उत्तर
We know that P = VI
∴ I = `"P"/"V" = 220/50 = 4.4`
Heat produced in an immersion heater
H = I2Rt
H = (4.4)2 × 50 × t
H = 968 t Joules
and Heat needed = mcθ
where C is the sp. heat capacity of water
= 4.2 × 103 J/kgC = 5 × 4.2 × 103 × (100 - 30)
= 5 × 4.2 × 103 × 70 = 1470000 J.
But Heat lost = Heat gained
968 t = 1470000
t = `1470000/968`
t = 1518.59 secs
t = 1518.6 secs
t = 25.326 min.
t = 25.33 mins.
संबंधित प्रश्न
What is meant by "electric power"?
Electrical power P is given by the expression P = (Q × V) ÷ time. What do the symbols Q and V represent?
Name the physical quality which is measured in
(i) Kw (ii) kWh
Two bulbs are rated 60 W, 220 V and 60 W, 110 V respectively. Calculate the ratio of their
resistances
Water in an electric kettle connected to a 220 V supply took 5 minutes to reach its boiling point. How long would it have taken if the supply voltage had fallen to 200 V?
The coil of an electric bulb takes 40 watts to start glowing. If more than 40 W are supplied, 60% of the extra power is converted into light and the remaining into heat. The bulb consumes 100 W at 220 V. Find the percentage drop in the light intensity at a point if the supply voltage changes from 220 V to 200 V.
Why does not the heating coil produce any visible light? in an electric stove.
If the rating of an electric bulb is 100W – 230V, Explain its meaning.
What is the order of current drawn by appliances connected to the ‘light circuit’ of a household?
An electric heater is rated 220 V, 550 W. Calculate the electrical energy consumed in 3 hours?